Price : $30.09
You Save : $9.90 (25%)

Item Description
Amazon.com Item Description
The Kidde PI2010 Battery-Operated Dual Sensor Smoke Alarm combines photoelectric and ionization sensing technologies into one unit to offer broad detection against smoldering and flaming fires. Specialists advocate that for optimal protection you have both forms of sensing engineering in your home. This smoke alarm's trademarked Hush function makes it possible for you to silence nuisance alarms, although an indicator LED and test function let you simply confirm that the alarm is working.
The Kidde PI2010 Smoke Alarm:
- Employs each photoelectric and ionization sensors.
- Characteristics a hush button to silence the alarm for non-emergency circumstances like a smoky dinner.
- Compact style blends in seamlessly with your household decor.
- Wire-in smoke alarm with 9V battery backup.
With two several sensors, you'll get warnings sooner no matter the kind of fire. .
Be assured of your home's security with the PI2010 smoke alarm. .Dual-Sensor Engineering for Improved SafetyExperts divide home fires into two groups: flaming and smoldering. Flaming fires result from flammable liquids and cooking accidents, although smoldering fires most quite often take place when smoking supplies, such as cigarettes, are left unattended. Ionization smoke sensors may very well detect smaller, much less visible fire particles, like those made by flaming fires, sooner than photoelectric sensors. Even so, photoelectric sensors are may well detect larger, significantly more visible fire particles, such as those produced by smoldering fires, sooner than ionization sensors. Every single should pass identical efficiency standards to obtain third-party approval and meet Underwriters Laboratories (UL) 217, the independent standard to which alarms are listed. Since you don't know what type of fire you will have in your house, experts suggest installing each varieties of engineering for optimal protection.
Experts Suggest Protection from Both Types of FiresVirtually each recognized fire authority recommends the installation of both ionization and photoelectric alarms in order to maximize protection from either flaming or smoldering fires. Kidde provides photoelectric smoke alarms, ionization smoke alarms, and dual sensor alarms, which mix each technologies in one unit. Regardless of the engineering, the most essential factor is to assure that you have operating smoke alarms on every floor of your property, inside every single bedroom and outside sleeping locations. Research show placing alarms in both bedrooms and hallways could boost a family's escape time by up to 15 minutes.
Fire Authorities recommending both smoke alarm technologies:
Trademarked Hush Function for ConvenienceBy pressing the Hush button, you can without difficulty and safely silence nuisance alarms brought on by non-emergency scenarios, such as overcooked dinners.
This feature desensitizes the alarm for around seven minutes. During this time, the alarm chirps every single 30 to 40 seconds. If the smoke is too dense, the Hush feature is overridden and the alarm still sounds, and the alarm automatically resets at the end of the seven minutes. This handy security measure eliminates the temptation to remove the alarm's battery, which creates an unsafe circumstance.
Wire-in Smoke Alarm with Dependable 9-Volt Battery Backup, Indicator LED, and Test FeatureBecause a smoke alarm only helps guard you if it really is working, this unit capabilities a red LED that flashes every 30 to 40 seconds to indicate that it is operating properly. For extra peace of mind, the alarm contains a test/reset button that enables you to periodically test its circuitry and horn.
The PI2010 is a wire-in smoke alarm with 9V battery backup, which delivers continuous protection against smoke and fire hazards even for the duration of power outages. The unit presents a low battery warning that challenges a brief chirp every 30 to 40 seconds for at least seven days before losing power, letting you know it's time to adjust the battery.
The unit measures just 5.75 inches in diameter and 1.eight inches deep, and it characteristics a neutral, white finish. It features tamper resist functions to deter vandalism or theft.
This dual-sensor smoke alarm is UL listed, so you can be confident of its quality, and it is backed by a 10-year restricted warranty.
About Kidde: A UTC Fire Security BrandRenowned for international leadership in fire detection and suppression, Kidde delivers options ranging from transportable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems.
Kidde is a UTC Fire Safety brand, with a history that's rich with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's very first wireless networked smoke detectors in 2004.
What is in the BoxDual Sensor photoelectric/ionization smoke alarm with mounting bracket and mounting hardware, 9-volt battery, 10-year restricted warranty, and bilingual user's manual.
The Kidde PI2010 is a breeze to operate and has a hush function to temporarily silence alarms.
From the Manufacturer
The Kidde PI2010 is a 120VAC, wire-in smoke alarm with 9V battery backup. This smoke alarm functions as a stand alone unit or in an interconnected system. The Kidde PI2010 characteristics hush, permitting you to quickly silence nuisance alarms and also contains a tamper resist functions that deters tampering and theft. The PI2010 consists of a quick connect power harness that permits for fast and painless installation. This smoke alarm combines both photoelectric and ionization sensors. Ionization sensing alarms might possibly detect invisible fire particles (connected with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms could detect visible particles (connected with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that each ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various sorts of fire that can occur inside the home. The Kidde PI2010, 120VAC, wire-in smoke alarm with 9V battery backup offers continuous protection against smoke and fire hazards, even during power outages. The combination of ionization and photoelectric sensors present the top protection against both quickly flaming and slow smoldering fires. The Kidde PI2010 interconnects with up to 24 Kidde devices of which 18 can be initiating. This unit also includes flashing LEDs to signal the alarm is functioning adequately, a low battery warning and a loud 85dB alarm. The Kidde PI2010 is UL Listed and contains a ten year limited battery.

Customer Evaluations
I didn't know about replacing smoke alarms each and every decade till especially recently. The units in my property had been two decades old, hardwired AC with no battery backup. They tested fine but just after twenty years it is undoubtedly time to replace them by any standard. There are three in my house, a single on each and every floor.
Just after performing a bit of study and becoming a sensible consumer, I decided the PI2010 was the best option out there. I purchased them up at a nearby massive box residence center simply because the cost was very competitive with Amazon and I didn't have to wait for shipping (even absolutely free super saver shipping).
In the box was a mounting bracket, three-wire harness, instructions, screws, and the smoke alarm.
Installation was a breeze - shut off the power at the circuit breaker initial, removed the old alarms and harnesses next. The instructions with the PI2010 created it clear to not pull out the battery shipping tab till the units all had AC power applied. The mounting bracket was able to use the current screws so I didn't have to even get rid of them from the ceiling box. The harness wired up conveniently and following plugging it into the alarm it only took a compact twist to secure it to the mounting mounting bracket. Right after turning the power back on, I pulled the battery tabs out of each and every alarm. I tested every 1, and had a friend make confident the units on the other floors sounded also.
The alarms in this model are about twice as loud as my old smoke alarms, practically ear splitting loud so I think there is no likelihood to sleep via it. A green LED tells you it has AC power and there is a red LED that flashes just about every so normally to say it's operating. I may very well locate the 'hush' feature valuable for my occasional kitchen disaster, but fanning a cookie sheet is my usual move when I burn a thing also crispy.
The fact that the battery compartment is on the backside does not detract from the alarm. just a hassle-free quarter twist and the unit comes off the bracket. On that note, it does have an anti-tamper function that if you select to activate, removing it from the bracket calls for a read by means of the instructions and a lot significantly more work.
All in all, it was a breeze to install, it looks and feels specialist, it is the loudest alarm I've ever heard, and the hush function is fantastic.
I program on extending the wiring and installing these in each of the bedrooms, above and beyond minimal code.
Just purchased a property and the smoke detector was more than 20 years old. After hunting at the many smoke detectors on the internet, realized that I required a dual alarm with both photoelectric and ionization sensors for ideal coverage. Most of the less expensive alarms are only ionization. This unit met my demands perfectly...
Dual sensor
Challenging Wired (earlier detector was hard wired)
Battery Backup
Hush button (for false alarms)
Got the alarm a couple of days ahead of the estimated arrival date. Pulled the pieces out of the box (directions, bracket, unit, and wiring harness), did a quick look by means of the directions and went to work. It actually only took me about fifteen minutes to install...most of that time taking the old units bracket down and putting up the new 1. The wiring harness has 3 wires...black, white and red...but the red one has a plastic cover over the finish in case you do not desire to wire various alarms together.
Just after attaching the needed wires to the home electric with wirenuts and electrical tape, just attach the bracket to the wall, make the positive the included battery is isntalled in the unit, plug the wiring harness into the back of the unit and attach to bracket. Piece o' cake.
If your dwelling currently has a particular wiring harness, and you don't want to mess with electrical, I believe there are adaptors out there for the back of this unit as properly that can accept other shaped harnesses. Incredibly convenient, if you want them. For me, it was pretty uncomplicated to cut the power and hook it up myself.

Related Product
Scansys Cctv Tester, 3.5Coax Cable Cutter for RG59 RG6 CCTV Satellite TV Antenna Installations
No comments: